Commercial heat pumps

Find the heat pump that meets your design point.

Compare 64 commercial heat pump vendors, including 33 with documented air-to-water equipment. Shortlist by heat source, delivery temperature and refrigerant, then open the manufacturer data and independent evidence for each entry. Send the same load, temperatures and electrical supply to your shortlisted vendors so their quotes address the same design point.

Evidence reviewed CSV JSON

A. O. SmithCAHP-120 100Air-to-water——65.61R134a2026-11-28
AdvansorValueBox 600Air-to-water600 kW (published project capacity)—953R7442026-11-28
AermecPRM 0504Air-to-water—101.72752R2902026-11-28
CarrierAquaSnap 61AQAir-to-water40–130 kW nominal heating, 61AQ family—752R2902026-11-28
Clade Engineering SystemsAcer 2Air-to-water—1302702R7442026-11-28
ClivetSHEEN PRO (WiSAN-PSE1 10.1–45.2)Air-to-water25–55 kW (family product-page capacity)—771R2902026-11-28
Colmac WaterHeatCxV seriesAir-to-water———R454B2026-11-28
COMBITHERMHigh Temperature Heat PumpsWaste heat-to-process heat20–1,000 kW across the manufacturer range——HFO / HFC or non-halogenated configuration2026-11-28
Copeland / VilterVilter VQ95Water-to-water1–5 MW on one skid——R7172026-11-28
DaikinEWYT-BAir-to-water85–640 kW heating, EWYT-B installation manual range——R322026-11-28
ECO₂ SystemsSANCO₂ GS5-45HPCAir-to-water4.5 kW nominal per heat pump—62.81R7442026-11-28
ecop TechnologiesRotation Heat PumpWaste heat-to-process heat700 kW per core; 5.6 MW illustrated with eight cores——ecop fluid 12026-11-28
ELCOAEROTOP EVO LN 105Air-to-water—81.91——2026-11-28
Energy MachinesEMT 1380-1-4-ECOWater-to-water—4763—R1234ze2026-11-28
EnerinHoegTempWaste heat-to-steam250–1,000 kW per module—2501R7042026-11-28
EverllenceTCC HPU28Water-to-water—9,67011501R7442026-11-28
FenagyH-600 (H-range)Air-to-water and Water-to-water600 kW (catalog capacity per unit)—851R7442026-11-28
Flow Environmental SystemsANSWR Model CAir- or water-to-water—66.8282.22R7442026-11-28
FriothermUnitopWater-to-water3–35 MW across custom single- and two-stage systems—1201—2026-11-28
FutraheatGreensteamWaste heat-to-steamUp to 400 kW thermal per unit——R1233zd in the Greensteam 330 brewery installation2026-11-28
GallettiWBEWater-to-water45–220 kW (family catalog range)—901R515B2026-11-28
GENERAL (formerly Fujitsu General)AIRSTAGE VU-7Air-to-air6–32 ton VRF system range——R322026-11-28
GKTCompriVAPWaste heat-to-steamUp to 47 MW thermal for the BASF Ludwigshafen project———2026-11-28
HEATENHeatBooster HBL4-W/WWater-to-water0.8–2.5 MW thermal, HBL4-W/W envelope—2001Hydrocarbon or HFO configuration2026-11-28
HiRefKSWWater-to-waterUp to 180 kW (single circuit)—802—2026-11-28
IntellihotElectron iE6Air-to-waterUp to 300,000 Btu/h for the iE6——R7442026-11-28
Johnson Controls / SabroeHitemHPWaste heat-to-water100–1,000 kW across the range—1221R600 / R600a2026-11-28
KeyterZIRAN PRO KWRAir-to-water41–253 kW (published thermal power, reversible and cooling-only units)——R2902026-11-28
KobelcoSteam Grow Heat Pump SGH120Water-to-steam—3701—R245fa2026-11-28
Laars Heating SystemsE-Therm ECHV0325Air-to-water—952—R7442026-11-28
LG ElectronicsMulti V i ZRUM096DTE6Air-to-air103,000 BTU/h high heating at 47°F, ducted rating shown in LG submittal——R322026-11-28
LochinvarVeritus AHP140Air-to-water136,881 BTU/h maximum output under DOE test conditions40.13—R513A2026-11-28
Lync by WattsAegis A 250Air-to-water—61.53823R7442026-11-28
Mayekawaunimo AWAir-to-water—741901R7442026-11-28
Mitsubishi ElectricHeat2O QAHV-N136TAU-HPBAir-to-water—40271.12R7442026-11-28
Mitsubishi Heavy Industries Thermal SystemsETW-SWater-to-water—62711301R134a2026-11-28
MTAiCYGNUS N HP 019Air-to-water—66.32783R2902026-11-28
MultistackARPAir-to-water10–600 ton system range across linked modules, manufacturer listing———2026-11-28
Nyle Water Heating SystemsC90AAir-to-water95,500 BTU/h nominal DOE capacity26.4368.33R513A2026-11-28
OCHSNER EnergietechnikIWWDS 430 R4bWater-to-water500 kW heat supply capacity in Annex 58 exhibit—1301R1233zd2026-11-28
OilonChillHeat P30–P450Waste heat-to-water30–450 kW at B0/W35 with R134a—1203R134a for B0/W35 range figures2026-11-28
Olvondo TechnologyHighLiftWaste heat-to-steam750 kW rated output——R7042026-11-28
PanasonicBig Aquarea T-CAP WH-WXG30ME8Air-to-water—302752R2902026-11-28
PILLERPILLER Industrial Heat PumpWaste heat-to-steam10 MW in the IEA EPDM rubber stripper case——R718 in the IEA EPDM case2026-11-28
QpinchQpinch Heat TransformerWaste heat-to-steam0.5 MW nominal smallest standard unit; 15 MW largest engineered design——Water / phosphoric acid2026-11-28
QvantumQA50Air-to-water—503703R2902026-11-28
Rank ORCHP (HTHP series)Brine-to-water250–600 kW (portal thermal capacities; model-specific rating point unpublished)—1501R1233zd(E) / R1336mzz(Z) / R245fa2026-11-28
RheemHPHD-60VNU-201Air-to-waterUp to 84,752 BTU/h heating (110°F air and 100°F leaving water)—65.63R134a2026-11-28
RhossPOKER-P THAETP 250Air-to-water47.4–190.5 kW (one to four modules)47.42752R2902026-11-28
SamsungDVM S2 AM100AXVAGH/EUAir-to-air31.5 kW rated heating for AM100AXVAGH/EU, Samsung technical data book——R410A2026-11-28
SCM FrigoSMART SHP W110Water-to-water—1094854R7442026-11-28
Siemens EnergyHigh-temperature industrial heat pumpWaste heat-to-waterUp to 70 MW thermal—1501—2026-11-28
SKADECSH.F. R600Water-to-water400–2,200 kW (SH.F. catalog heating range)—903R600a2026-11-28
SpillingSpilling steam compressorSteam-to-steamApproximately 1–20 t/h steam flow——R718 in reviewed Spilling Steam Compressor2026-11-28
Star RefrigerationWater Source NeatpumpWater-to-water700 kW–10 MW thermal modular range—1301R7172026-11-28
Strebel Heating TechnologyS-ASX-LPiAir-to-water20.5–108 kW min-to-max range at A7/W35, across configurations—681—2026-11-28
SwegonEPSILON Zero Hi HP 30Air-to-water14–45 kW (family heating range)—754R2902026-11-28
ThermonovaNova 110Air-to-water45–110 kW (Nova 110 range)—701R2902026-11-28
TraneAscend ACXAir-to-water1,000–2,500 MBH heating, Ascend ACX family—62.81R454B2026-11-28
TurbodenHeat Pump to SteamWaste heat-to-steamUp to 15 t/h of steam at 2 bar(a), direct generation———2026-11-28
Viessmann Climate SolutionsVitocal 200-A PROAir-to-water32, 64 and 128 kW rated heat output—651—2026-11-28
WaterDrop by Small Planet SupplyModular DropletsAir-to-water——65.61R7442026-11-28
WaterkotteIndustrial Line 8060.7Brine-to-water and Water-to-waterUp to 60 kW (catalog unit maximum)——R2902026-11-28
WOLFCHA-20/24-400V-M2 CS-e9-D2Air-to-water5.6–24.0 kW at A7/W35 (CHA 20/24 range)—701R2902026-11-28

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

Sending shares your request and contact details with matching heat pump suppliers through Commercial Heat Pump Vendors so they can reply. Privacy policy

Commercial heat pump buying questions

How do I shortlist a commercial heat pump?

Start with the heat source and the delivery medium. Use your peak heating load, source temperature and required supply and return temperatures to request equipment selections.

What should I include when requesting pricing?

Send the design load, source and delivery temperatures, site location, available voltage and preferred delivery date. Ask for equipment and installation as separate line items.

What determines how much heat a unit can deliver?

Heating output depends on the entering source condition and required delivery temperature. Read each rated output together with its test point and ask for a selection at your design conditions.

Where do I find model-level listings?

Open the certification and qualified-list guide to see the exact variant, issuing body and date. Find the full lookup link in each applicable vendor profile.